Prestazioni assolute
Temperature
7V |
Idle |
Load |
Enermax Liqtech
240 |
32 °C |
50 °C |
Deepcool MaelStrom240 |
31 °C |
51 °C |
Corsair H75 Single
Fan |
32 °C |
51 °C |
Corsair H90 Single
Fan |
33 °C |
51 °C |
Corsair H110 Dual
Fan |
33 °C |
51 °C |
Enermax Liqtech 120X |
32 °C |
51 °C |
Noctua NH-D15 Dual Fan |
33 °C |
51 °C |
Noctua NH-U12S
Dual Fan |
33 °C |
53 °C |
Noctua NH-D15 Single Fan |
34 °C |
53 °C |
Raijintek Nemesis Dual Fan |
34 °C |
54 °C |
Deepcool MaelStrom120 |
35 °C |
55 °C |
Enermax ETS-T40
White Claster |
35 °C |
56 °C |
Raijintek Nemesis Single Fan |
35 °C |
56 °C |
Noctua NH-U12S
Single Fan |
34 °C |
57 °C |
Raijintek Themis
EVO |
34 °C |
57 °C |
Raijintek Pallas |
37 °C |
59 °C |
Cooler
Master Hyper 103 |
36 °C |
60 °C |
Alpenföhn
Matterhorn Pure |
36 °C |
61 °C |
Prolimatech Lynx |
35 °C |
63 °C |
Thermolab Bada
2010 |
39 °C |
64 °C |
Scythe IORI
Scior-1000 |
39 °C |
65 °C |
Thermolab ITX30 |
38 °C |
75 °C |
Intel Stock |
39 °C |
83 °C |
Thermolab LP-53 |
38 °C |
69 °C |
Scythe Ashura |
36 °C |
58 °C |
Enermax ETS-T40
Black Twister |
34 °C |
56 °C |
Per misurare la capacità di raffreddamento abbiamo preso le temperature in idle con ventola a 7V e in full con ventola a 12V. La temperatura in idle è la più bassa della CPU e viene rilevata dopo 10 minuti di invattività. La temperatura in full si ottiene utilizzando il benchmark wPrime v2.10. Il test di wPrime dura 4 minuti e carica tutti e gli i 8 thread. La temperatura ambiente è di 25°C.
12V |
Idle |
Load |
Noctua NH-D15 Dual Fan |
32 °C |
50 °C |
Corsair H90 Single
Fan |
32 °C |
50 °C |
Corsair H110 Dual
Fan |
32 °C |
50 °C |
Deepcool MaelStrom240 |
33 °C |
50 °C |
Corsair H75 Single
Fan |
32 °C |
51 °C |
Enermax Liqtech
240 |
32 °C |
51 °C |
Noctua NH-U12S
Dual Fan |
33 °C |
51 °C |
Deepcool MaelStrom120 |
33 °C |
53 °C |
Enermax Liqtech
120X |
31 °C |
53 °C |
Noctua NH-U12S
Single Fan |
33 °C |
53 °C |
Raijintek Nemesis Dual Fan |
33 °C |
54 °C |
Raijintek Themis
EVO |
33 °C |
54 °C |
Enermax ETS-T40
White Claster |
34 °C |
54 °C |
Noctua NH-D15 Single Fan |
33 °C |
55 °C |
Raijintek Nemesis Single Fan |
34 °C |
55 °C |
Prolimatech Lynx |
34 °C |
55 °C |
Raijintek Pallas |
36 °C |
56 °C |
Alpenföhn
Matterhorn Pure |
34 °C |
57 °C |
Cooler
Master Hyper 103 |
36 °C |
58 °C |
Scythe IORI
Scior-1000 |
37 °C |
60 °C |
Thermolab Bada
2010 |
39 °C |
64 °C |
Thermolab ITX30 |
36 °C |
69 °C |
Intel Stock |
35 °C |
70 °C |
Thermolab LP-53 |
37 °C |
65 °C |
Scythe Ashura |
34 °C |
55 °C |
Enermax ETS-T40
Black Twister |
35 °C |
55 °C |
Velocità ventole
|
7 Volt |
12 Volt |
Raijintek Nemesis
Single Fan |
840 rpm |
1'180 rpm |
Raijintek Nemesis
Dual Fan |
780 rpm |
1'200 rpm |
Enermax Liqtech
240 |
750 rpm |
1'300 rpm |
Raijintek Pallas |
960 rpm |
1'440 rpm |
Scythe Ashura |
600 rpm |
1'440 rpm |
Noctua NH-U12S
Dual Fan |
900 rpm |
1'500 rpm |
Noctua NH-U12S
Single Fan |
900 rpm |
1'500 rpm |
Corsair H90 Single
Fan |
960 rpm |
1'500 rpm |
Corsair H110 Dual
Fan |
960 rpm |
1'500 rpm |
Raijintek Themis
EVO |
960 rpm |
1'500 rpm |
Alpenföhn
Matterhorn Pure |
660 rpm |
1'530 rpm |
Noctua NH-D15 Dual Fan |
960 rpm |
1'560 rpm |
Noctua NH-D15 Single Fan |
1'020 rpm |
1'560 rpm |
Prolimatech Lynx |
600 rpm |
1'740 rpm |
Enermax ETS-T40
White Claster |
1'260 rpm |
1'860 rpm |
Enermax ETS-T40
Black Twister |
1'020 rpm |
1'860 rpm |
Thermolab Bada
2010 |
1'140 rpm |
1'980 rpm |
Corsair H75 Single
Fan |
1'200 rpm |
1'980 rpm |
Intel Stock |
1'260 rpm |
2'040 rpm |
Enermax Liqtech
120X |
1'270 rpm |
2'050 rpm |
Thermolab LP-53 |
300 rpm |
2'180 rpm |
Scythe IORI
Scior-1000 |
280 rpm |
2'220 rpm |
Deepcool MaelStrom240 |
1'440 rpm |
2'220 rpm |
Deepcool MaelStrom120 |
1'500 rpm |
2'280 rpm |
Cooler
Master Hyper 103 |
1'580 rpm |
2'400 rpm |
Thermolab ITX30 |
1'620 rpm |
2'580 rpm |
Velocità RPM a 7 e 12V.
Rumore
|
7 Volt |
12 Volt |
Intel Stock |
33.3 dBA |
37.1 dBA |
Enermax Liqtech
240 |
33.5 dBA |
37.0 dBA |
Noctua NH-U12S
Single Fan |
32.3 dBA |
37.4 dBA |
Noctua NH-D15 Dual Fan |
32.2 dBA |
37.4 dBA |
Alpenföhn
Matterhorn Pure |
32.3 dBA |
38.4 dBA |
Noctua NH-D15 Single Fan |
33.7 dBA |
38.9 dBA |
Thermolab ITX30 |
33.4 dBA |
38.9 dBA |
Raijintek Pallas |
34.7 dBA |
39.3 dBA |
Cooler
Master Hyper 103 |
34.2 dBA |
39.5 dBA |
Noctua NH-U12S
Dual Fan |
33.4 dBA |
39.6 dBA |
Thermolab LP-53 |
31.2 dBA |
39.7 dBA |
Raijintek Themis
EVO |
33.9 dBA |
40.1 dBA |
Scythe IORI
Scior-1000 |
32.8 dBA |
40.3 dBA |
Prolimatech Lynx |
33.0 dBA |
40.3 dBA |
Thermolab Bada
2010 |
32.3 dBA |
40.4 dBA |
Enermax Liqtech
120X |
33.4 dBA |
40.6 dBA |
Enermax ETS-T40
Black Twister |
33.1 dBA |
40.7 dBA |
Enermax ETS-T40
White Claster |
33.3 dBA |
40.7 dBA |
Scythe Ashura |
32.0 dBA |
41.0 dBA |
Corsair H90 Single
Fan |
34.1 dBA |
41.2 dBA |
Corsair H75 Single
Fan |
34.5 dBA |
41.7 dBA |
Corsair H110 Dual
Fan |
33.3 dBA |
41.7 dBA |
Raijintek Nemesis Dual Fan |
36.1 dBA |
43.6 dBA |
Raijintek Nemesis
Dual Fan |
36.1 dBA |
43.6 dBA |
Deepcool MaelStrom120 |
38.2 dBA |
46.9 dBA |
Deepcool MaelStrom240 |
39.7 dBA |
49.3 dBA |
Il misuratore di decibel (Volcraft SL-200) è posizionato a 1 metro dal dissipatore. Le misurazioni vengono effettuate in una stanza priva di altri rumori. 32 dBA è la rilevazione più bassa che possiamo ottenere. Anche le misurazioni a 7 e 12V sono ottenute in questa stanza.