Performance Absolut
Temperatur
7V |
Idle |
Load |
Enermax Liqtech
120X |
32 °C |
50 °C |
Corsair H75 Single
Fan |
32 °C |
51 °C |
Noctua NH-D15 Dual Fan |
33 °C |
51 °C |
Noctua NH-U12S
Dual Fan |
33 °C |
53 °C |
Noctua NH-D15 Single Fan |
34 °C |
53 °C |
Raijintek Nemesis Dual Fan |
34 °C |
54 °C |
Enermax ETS-T40
White Claster |
35 °C |
56 °C |
Raijintek Nemesis Single Fan |
35 °C |
56 °C |
Noctua NH-U12S
Single Fan |
34 °C |
57 °C |
Raijintek Themis
EVO |
34 °C |
57 °C |
Raijintek Pallas |
37 °C |
59 °C |
Cooler
Master Hyper 103 |
36 °C |
60 °C |
Alpenföhn
Matterhorn Pure |
36 °C |
61 °C |
Prolimatech Lynx |
35 °C |
63 °C |
Thermolab Bada
2010 |
39 °C |
64 °C |
Scythe IORI
Scior-1000 |
39 °C |
65 °C |
Thermolab ITX30 |
38 °C |
75 °C |
Intel Stock |
39 °C |
83 °C |
Um die Kühlkapazität zu messen, nehmen wir die
Temperaturen im Leerlauf sowie unter Last, wobei die Lüfter mit 7 Volt sowie 12V
betrieben werden.
12V |
Idle |
Load |
Enermax Liqtech
120X |
31 °C |
44 °C |
Noctua NH-D15 Dual Fan |
32 °C |
50 °C |
Corsair H75 Single
Fan |
32 °C |
51 °C |
Noctua NH-U12S
Dual Fan |
33 °C |
51 °C |
Noctua NH-U12S
Single Fan |
33 °C |
53 °C |
Raijintek Nemesis Dual Fan |
33 °C |
54 °C |
Raijintek Themis
EVO |
33 °C |
54 °C |
Enermax ETS-T40
White Claster |
34 °C |
54 °C |
Noctua NH-D15 Single Fan |
33 °C |
55 °C |
Raijintek Nemesis Single Fan |
34 °C |
55 °C |
Prolimatech Lynx |
34 °C |
55 °C |
Raijintek Pallas |
36 °C |
56 °C |
Alpenföhn
Matterhorn Pure |
34 °C |
57 °C |
Cooler
Master Hyper 103 |
36 °C |
58 °C |
Scythe IORI
Scior-1000 |
37 °C |
60 °C |
Thermolab Bada
2010 |
39 °C |
64 °C |
Thermolab ITX30 |
36 °C |
69 °C |
Intel Stock |
35 °C |
70 °C |
Lüfterdrehzahl
|
7 Volt |
12 Volt |
Raijintek Nemesis
Single Fan |
840 rpm |
1'180 rpm |
Raijintek Pallas |
960 rpm |
1'440 rpm |
Raijintek Nemesis
Dual Fan |
780 rpm |
1'200 rpm |
Noctua NH-U12S
Dual Fan |
900 rpm |
1'500 rpm |
Noctua NH-U12S
Single Fan |
900 rpm |
1'500 rpm |
Raijintek Themis
EVO |
960 rpm |
1'500 rpm |
Alpenföhn
Matterhorn Pure |
660 rpm |
1'530 rpm |
Noctua NH-D15 Dual Fan |
960 rpm |
1'560 rpm |
Noctua NH-D15 Single Fan |
1'020 rpm |
1'560 rpm |
Enermax ETS-T40
White Claster |
1'260 rpm |
1'860 rpm |
Prolimatech Lynx |
600 rpm |
1'740 rpm |
Corsair H75 Single
Fan |
1'200 rpm |
1'980 rpm |
Thermolab Bada
2010 |
1'140 rpm |
1'980 rpm |
Intel Stock |
1'260 rpm |
2'040 rpm |
Enermax Liqtech
120X |
1'270 rpm |
2'050 rpm |
Scythe IORI
Scior-1000 |
280 rpm |
2'220 rpm |
Cooler
Master Hyper 103 |
1'580 rpm |
2'400 rpm |
Thermolab ITX30 |
1'620 rpm |
2'580 rpm |
Lüfterdrehzahlen (RPM) bei 7 Volt
sowie 12 Volt.
Lautstärke
|
7 Volt |
12 Volt |
Intel Stock |
33.3 dBA |
37.1 dBA |
Noctua NH-U12S
Single Fan |
32.3 dBA |
37.4 dBA |
Noctua NH-D15 Dual Fan |
32.2 dBA |
37.4 dBA |
Alpenföhn
Matterhorn Pure |
32.3 dBA |
38.4 dBA |
Noctua NH-D15 Single Fan |
33.7 dBA |
38.9 dBA |
Thermolab ITX30 |
33.4 dBA |
38.9 dBA |
Raijintek Pallas |
34.7 dBA |
39.3 dBA |
Cooler
Master Hyper 103 |
34.2 dBA |
39.5 dBA |
Noctua NH-U12S
Dual Fan |
33.4 dBA |
39.6 dBA |
Raijintek Themis
EVO |
33.9 dBA |
40.1 dBA |
Scythe IORI
Scior-1000 |
32.8 dBA |
40.3 dBA |
Prolimatech Lynx |
33.0 dBA |
40.3 dBA |
Thermolab Bada
2010 |
32.3 dBA |
40.4 dBA |
Enermax Liqtech
120X |
33.4 dBA |
40.6 dBA |
Raijintek Nemesis Dual Fan |
36.1 dBA |
43.6 dBA |
Raijintek Nemesis
Dual Fan |
36.1 dBA |
43.6 dBA |
Enermax ETS-T40
White Claster |
33.3 dBA |
40.7 dBA |
Corsair H75 Single
Fan |
34.5 dBA |
41.7 dBA |
Das Schallmessgerät
(Voltcraft SL-200) platzieren wir einen meter entfern vom Kühler. Die Messungen
werden in einem ruhigen Raum durchgeführt, wobei der gemssene
Umgebungsschallpegel 32 dBA berägt. Bei diesem Geräuschpegel hört man sich
selbst beim Atmen. Auch diese Messungen wurden mit den Lüftern bei 7 Volt sowie
12 Volt durchgeführt.