Performance Absolut
Temperatur
7V |
Idle |
Load |
Enermax Liqtech
120X |
32 °C |
50 °C |
Corsair H75 Single
Fan |
32 °C |
51 °C |
Noctua NH-U12S
Dual Fan |
33 °C |
53 °C |
Raijintek Nemesis Dual Fan |
34 °C |
54 °C |
Enermax ETS-T40
Black Twister |
34 °C |
56 °C |
Enermax ETS-T40
While Cluster |
35 °C |
56 °C |
Raijintek Nemesis Single Fan |
35 °C |
56 °C |
Noctua NH-U12S
Single Fan |
34 °C |
57 °C |
Raijintek Themis
EVO |
34 °C |
57 °C |
Scythe Ashura |
36 °C |
58 °C |
Raijintek Pallas |
37 °C |
59 °C |
Cooler
Master Hyper 103 |
36 °C |
60 °C |
Alpenfohn
Matterhorn Pure |
36 °C |
61 °C |
Prolimatech Lynx |
35 °C |
63 °C |
Thermolab Bada
2010 |
39 °C |
64 °C |
Thermolab LP53 |
38 °C |
69 °C |
Scythe IORI
Scior-1000 |
39 °C |
65 °C |
Thermolab ITX30 |
38 °C |
75 °C |
Intel Stock |
39 °C |
83 °C |
Um die Kühlkapazität zu messen, nehmen wir die
Temperaturen im Leerlauf sowie unter Last, wobei die Lüfter mit 7 Volt sowie 12V
betrieben werden.
12V |
Idle |
Load |
Enermax Liqtech
120X |
31°C |
44 °C |
Corsair H75 Single
Fan |
32 °C |
51 °C |
Noctua NH-U12S
Dual Fan |
33 °C |
51 °C |
Noctua NH-U12S
Single Fan |
33 °C |
53 °C |
Raijintek Themis
EVO |
33 °C |
54 °C |
Raijintek Nemesis Dual Fan |
33 °C |
54 °C |
Enermax ETS-T40
While Cluster |
34 °C |
54 °C |
Enermax ETS-T40
Black Twister |
35 °C |
55 °C |
Raijintek Nemesis Single Fan |
34 °C |
55 °C |
Prolimatech Lynx |
34 °C |
55 °C |
Scythe Ashura |
34 °C |
55 °C |
Raijintek Pallas |
36 °C |
56 °C |
Alpenfohn
Matterhorn Pure |
34 °C |
57 °C |
Cooler
Master Hyper 103 |
36 °C |
58 °C |
Scythe IORI
Scior-1000 |
37 °C |
60 °C |
Thermolab Bada
2010 |
39 °C |
64 °C |
Thermolab LP53 |
37 °C |
65 °C |
Thermolab ITX30 |
36 °C |
69 °C |
Intel Stock |
35 °C |
70 °C |
Lüfterdrehzahl
|
7 Volt |
12 Volt |
Raijintek Nemesis
Single Fan |
840 rpm |
1'180 rpm |
Raijintek Nemesis
Dual Fan |
780 rpm |
1'200 rpm |
Scythe Ashura |
600 rpm |
1'440 rpm |
Raijintek Pallas |
960 rpm |
1'440 rpm |
Noctua NH-U12S
Dual Fan |
900 rpm |
1'500 rpm |
Noctua NH-U12S
Single Fan |
900 rpm |
1'500 rpm |
Raijintek Themis
EVO |
960 rpm |
1'500 rpm |
Alpenfohn
Matterhorn Pure |
660 rpm |
1'530 rpm |
Prolimatech Lynx |
600 rpm |
1'740 rpm |
Enermax ETS-T40
Black Twister |
1'020 rpm |
1'860 rpm |
Enermax ETS-T40
While Cluster |
1'260 rpm |
1'860 rpm |
Thermolab Bada
2010 |
1'140 rpm |
1'980 rpm |
Corsair H75 Single
Fan |
1'200 rpm |
1'980 rpm |
Intel Stock |
1'260 rpm |
2'040 rpm |
Enermax Liqtech
120X |
1'270 rpm |
2'050 rpm |
Thermolab LP53 |
300 rpm |
2'180 rpm |
Scythe IORI
Scior-1000 |
280 rpm |
2'220 rpm |
Cooler
Master Hyper 103 |
1'580 rpm |
2'400 rpm |
Thermolab ITX30 |
1'620 rpm |
2'580 rpm |
Lüfterdrehzahlen (RPM) bei 7 Volt
sowie 12 Volt.
Lautstärke
|
7 Volt |
12 Volt |
Intel Stock |
33.3 dBA |
37.1 dBA |
Noctua NH-U12S
Single Fan |
32.3 dBA |
37.4 dBA |
Raijintek Nemesis Single Fan |
34.6 dBA |
38.0 dBA |
Alpenfohn
Matterhorn Pure |
32.3 dBA |
38.4 dBA |
Thermolab ITX30 |
33.4 dBA |
38.9 dBA |
Raijintek Pallas |
34.7 dBA |
39.3 dBA |
Cooler
Master Hyper 103 |
34.2 dBA |
39.5 dBA |
Noctua NH-U12S
Dual Fan |
33.4 dBA |
39.6 dBA |
Thermolab LP53 |
31.2 dBA |
39.7 dBA |
Raijintek Themis
EVO |
33.9 dBA |
40.1 dBA |
Scythe IORI
Scior-1000 |
32.8 dBA |
40.3 dBA |
Prolimatech Lynx |
33.0 dBA |
40.3 dBA |
Thermolab Bada
2010 |
32.3 dBA |
40.4 dBA |
Enermax Liqtech
120X |
33.4 dBA |
40.6 dBA |
Enermax ETS-T40
Black Twister |
33.1 dBA |
40.7 dBA |
Enermax ETS-T40
While Cluster |
33.3 dBA |
40.7 dBA |
Scythe Ashura |
32.0
dBA |
41.0 dBA |
Corsair H75 Single
Fan |
34.5 dBA |
41.7 dBA |
Raijintek Nemesis Dual Fan |
36.1 dBA |
43.6 dBA |
Das Schallmessgerät
(Voltcraft SL-200) platzieren wir einen meter entfern vom Kühler. Die Messungen
werden in einem ruhigen Raum durchgeführt, wobei der gemssene
Umgebungsschallpegel 32 dBA berägt. Bei diesem Geräuschpegel hört man sich
selbst beim Atmen. Auch diese Messungen wurden mit den Lüftern bei 7 Volt sowie
12 Volt durchgeführt.