Result Analysis and Discussion
Efficiency 115V
|
Load |
Efficiency |
20 % |
91.41 % |
50 % |
92.37 % |
100 % |
89.45 % |
The Platinum Energy
certification requirements (90% ; 92% ; 89%) are surpassed especially at 20% Load.
The full Load efficiency is a bit higher at 230V AC. This is in most PSU's the
case and mainly come out of the reason of lower losses in the AC filtering and
in the PFC at 230V AC. Unfortunately this 80Plus test report does not contain
Information about the 230V efficiency. The 230V AC 100% Load efficiency is
expected to be between 89.5-90.5%.
Output Stability
|
Load |
Rail |
Loading(A) |
Output |
20 % |
5V |
2.0 |
5.0 |
3.3V |
2.0 |
3.3 |
12V1 |
8.4 |
12.3 |
5VSB |
0.4 |
5.1 |
|
50 % |
5V |
5.0 |
5.0 |
3.3V |
5.0 |
3.3 |
12V1 |
21.0 |
12.2 |
5VSB |
1.0 |
5.1 |
|
100 % |
5V |
10.0 |
5.0 |
3.3V |
10.0 |
3.3 |
12V1 |
41.9 |
12.2 |
5VSB |
1.0 |
5.0 |
The Voltage Regulation of this PSU is very good. It makes use
of a DC-DC aproach, which means, that this PSU is mainly a 12V PSU and then generates its 5 and 3.3V
from 12V. This is a very modern approach, and since the Load is mainly on 12V it
makes a lot of sense. Like most PSUs which use this topology the voltage regulation
and the crossload test do not represent any issue.
Discuss this article in our