Thermolab Bada 2010 Review

Published by Hiwa Pouri on 17.03.14
Page:
« 1 2 3 (4) 5 6 »

Absolute Performance

Temperatures

7V Idle Load
Corsair H75 Single Fan 32 °C 51 °C
Noctua NH-U12S Dual Fan 33 °C 53 °C
Noctua NH-U12S Single Fan 34 °C 57 °C
Raijintek Pallas 37 °C 59 °C
Thermolab ITX30 38 °C 75 °C
Cooler Master Hyper 103 36 °C 60 °C
Alpenföhn Matterhorn Pure 36 °C 61 °C
Prolimatech Lynx 35 °C 63 °C
Thermolab Bada 2010 39 °C 64 °C
Intel Stock 39 °C 83 °C


To measure cooling capacity we took temperatures in idle and load with the fans at 7 and 12 V. The idle temperature represents the lowest temperature hit by the processor package after 10 minutes in idle. The load temperature is the highest temperature hit by the processor package after one pass of wPrime v2.10. The wPrime test takes 4 minutes and puts load on all 8 threads. Room temperature is 25°C.

12V Idle Load
Corsair H75 Single Fan 32 °C 51 °C
Noctua NH-U12S Dual Fan 33 °C 51 °C
Noctua NH-U12S Single Fan 33 °C 53 °C
Prolimatech Lynx 34 °C 55 °C
Raijintek Pallas 36 °C 56 °C
Alpenföhn Matterhorn Pure 34 °C 57 °C
Cooler Master Hyper 103 36 °C 58 °C
Thermolab Bada 2010 36 °C 59 °C
Thermolab ITX30 36 °C 69 °C
Intel Stock 35 °C 70 °C


Fan Speeds

  7 Volt 12 Volt
Raijintek Pallas 960 rpm 1'440 rpm
Thermolab ITX30 1620 rpm 2'580 rpm
Noctua NH-U12S Dual Fan 900 rpm 1'500 rpm
Noctua NH-U12S Single Fan 900 rpm 1'500 rpm
Alpenföhn Matterhorn Pure 660 rpm 1'530 rpm
Prolimatech Lynx 600 rpm 1'740 rpm
Corsair H75 Single Fan 1'200 rpm 1'980 rpm
Intel Stock 1'260 rpm 2'040 rpm
Thermolab Bada 2010 280 rpm 2'220 rpm
Cooler Master Hyper 103 1'580 rpm 2'400 rpm


Fan speeds (RPM) at 7 and 12 V.

Noise Levels

  7 Volt 12 Volt
Intel Stock 33.3 dBA 37.1 dBA
Noctua NH-U12S Single Fan 32.3 dBA 37.4 dBA
Thermolab ITX30 33.4 dBA 38.9 dBA
Alpenföhn Matterhorn Pure 32.3 dBA 38.4 dBA
Raijintek Pallas 34.7 dBA 39.3 dBA
Cooler Master Hyper 103 34.2 dBA 39.5 dBA
Noctua NH-U12S Dual Fan 33.4 dBA 39.6 dBA
Prolimatech Lynx 33.0 dBA 40.3 dBA
Thermolab Bada 2010 32.3 dBA 40.4 dBA
Corsair H75 Single Fan 34.5 dBA 41.7 dBA


Decibel meter (Voltcraft SL-200) has been placed 1 meter away from the cooler. Measurements are conducted in a quiet room, where there are no other noise source. 32 dBA is the lowest we can get in our room. Also here the measurements are conducted at 7 and 12 V.



Page 1 - Presentation / Specifications
Page 2 - Photo Gallery
Page 3 - Installation & Test Setup
Page 4 - Absolute Performance
Page 5 - PWM Performance
Page 6 - Conclusion




Navigate through the articles
Previous article Thermolab ITX30 Review Thermolab LP53 Review Next article
comments powered by Disqus

Thermolab Bada 2010 Review - Cooling > Aircooling - Reviews - ocaholic