Performances
brutes
Températures
7V |
Idle |
Load |
Enermax Liqtech
120X |
32 °C |
50 °C |
Corsair H75 Single
Fan |
32 °C |
51 °C |
Noctua NH-U12S
Dual Fan |
33 °C |
53 °C |
Raijintek Nemesis Dual Fan |
34 °C |
54 °C |
Enermax ETS-T40
White Cluster |
35 °C |
56 °C |
Raijintek Nemesis Single Fan |
35 °C |
56 °C |
Noctua NH-U12S
Single Fan |
34 °C |
57 °C |
Raijintek Themis
EVO |
34 °C |
57 °C |
Scythe Ashura |
36 °C |
58 °C |
Raijintek Pallas |
37 °C |
59 °C |
Cooler
Master Hyper 103 |
36 °C |
60 °C |
Alpenföhn Matterhorn Pure |
36 °C |
61 °C |
Prolimatech Lynx |
35 °C |
63 °C |
Thermolab Bada
2010 |
39 °C |
64 °C |
Thermolab LP53 |
38 °C |
69 °C |
Scythe IORI
Scior-1000 |
39 °C |
65 °C |
Thermolab ITX30 |
38 °C |
75 °C |
Intel Stock |
39 °C |
83 °C |
Pour mesurer les performances brutes nous avons
relevé les températures du processeur à 7 et 12 V. La température au
repos est la température la plus basse atteinte par le processeur (package)
après 10 minutes de repos. Pour la température en charge nous avons relevé la
température la plus haute atteinte par le processeur (package) sous wPrime
v2.10. Le processeur est sollicité pendant environs 4 minutes sur tous les
threads. La température de la pièce est 25°C.
12V |
Idle |
Load |
Enermax Liqtech
120X |
31 °C |
44 °C |
Corsair H75 Single
Fan |
32 °C |
51 °C |
Noctua NH-U12S
Dual Fan |
33 °C |
51 °C |
Noctua NH-U12S
Single Fan |
33 °C |
53 °C |
Raijintek Themis
EVO |
33 °C |
54 °C |
Raijintek Nemesis Dual Fan |
33 °C |
54 °C |
Enermax ETS-T40
White Cluster |
34 °C |
54 °C |
Raijintek Nemesis Single Fan |
34 °C |
55 °C |
Prolimatech Lynx |
34 °C |
55 °C |
Scythe Ashura |
34 °C |
55 °C |
Raijintek Pallas |
36 °C |
56 °C |
Alpenföhn
Matterhorn Pure |
34 °C |
57 °C |
Cooler
Master Hyper 103 |
36 °C |
58 °C |
Scythe IORI
Scior-1000 |
37 °C |
60 °C |
Thermolab Bada
2010 |
39 °C |
64 °C |
Thermolab LP53 |
37 °C |
65 °C |
Thermolab ITX30 |
36 °C |
69 °C |
Intel Stock |
35 °C |
70 °C |
Vitesses des ventilateurs
|
7 Volt |
12 Volt |
Raijintek Nemesis
Single Fan |
840 rpm |
1'180 rpm |
Raijintek Nemesis
Dual Fan |
780 rpm |
1'200 rpm |
Scythe Ashura |
600 rpm |
1'440 rpm |
Raijintek Pallas |
960 rpm |
1'440 rpm |
Noctua NH-U12S
Dual Fan |
900 rpm |
1'500 rpm |
Noctua NH-U12S
Single Fan |
900 rpm |
1'500 rpm |
Raijintek Themis
EVO |
960 rpm |
1'500 rpm |
Alpenföhn
Matterhorn Pure |
660 rpm |
1'530 rpm |
Prolimatech Lynx |
600 rpm |
1'740 rpm |
Enermax ETS-T40
White Cluster |
1'260 rpm |
1'860 rpm |
Thermolab Bada
2010 |
1'140 rpm |
1'980 rpm |
Corsair H75 Single
Fan |
1'200 rpm |
1'980 rpm |
Intel Stock |
1'260 rpm |
2'040 rpm |
Enermax Liqtech
120X |
1'270 rpm |
2'050 rpm |
Thermolab LP53 |
300 rpm |
2'180 rpm |
Scythe IORI
Scior-1000 |
280 rpm |
2'220 rpm |
Cooler
Master Hyper 103 |
1'580 rpm |
2'400 rpm |
Thermolab ITX30 |
1'620 rpm |
2'580 rpm |
Vitesse du(es) ventilateur(s) (RPM) à 7 et 12 V.
Nuisances sonores
|
7 Volt |
12 Volt |
Intel Stock |
33.3 dBA |
37.1 dBA |
Noctua NH-U12S
Single Fan |
32.3 dBA |
37.4 dBA |
Raijintek Nemesis Single Fan |
34.6 dBA |
38.0 dBA |
Alpenföhn
Matterhorn Pure |
32.3 dBA |
38.4 dBA |
Thermolab ITX30 |
33.4 dBA |
38.9 dBA |
Raijintek Pallas |
34.7 dBA |
39.3 dBA |
Cooler
Master Hyper 103 |
34.2 dBA |
39.5 dBA |
Noctua NH-U12S
Dual Fan |
33.4 dBA |
39.6 dBA |
Thermolab LP53 |
31.2 dBA |
39.7 dBA |
Raijintek Themis
EVO |
33.9 dBA |
40.1 dBA |
Scythe IORI
Scior-1000 |
32.8 dBA |
40.3 dBA |
Prolimatech Lynx |
33.0 dBA |
40.3 dBA |
Thermolab Bada
2010 |
32.3 dBA |
40.4 dBA |
Enermax Liqtech
120X |
33.4 dBA |
40.6 dBA |
Enermax ETS-T40
White Cluster |
33.3 dBA |
40.7 dBA |
Scythe Ashura |
32.0
dBA |
41.0 dBA |
Corsair H75 Single
Fan |
34.5 dBA |
41.7 dBA |
Raijintek Nemesis Dual Fan |
36.1 dBA |
43.6 dBA |
Pour le test des nuisances sonores nous utilisons
un Voltcraft SL-200 comme sonomètre placé à un mètre du système de
refroidissement. Les tests sont réalisés dans une pièce avec un niveau sonore
ambiant de 32dBA avec aucune autre source de bruit que le système de
refroidissement. Ici aussi nous avons fait les relevés à 7 et 12 V.