Absolute Performance
Temperatures
7V |
Idle |
Load |
Enermax Liqtech
120X |
32 °C |
50 °C |
Corsair H75 Single
Fan |
32 °C |
51 °C |
Noctua NH-U12S
Dual Fan |
33 °C |
53 °C |
Raijintek Nemesis Dual Fan |
34 °C |
54 °C |
Enermax ETS-T40
White Cluster |
35 °C |
56 °C |
Raijintek Nemesis Single Fan |
35 °C |
56 °C |
Noctua NH-U12S
Single Fan |
34 °C |
57 °C |
Raijintek Themis
EVO |
34 °C |
57 °C |
Scythe Ashura |
36 °C |
58 °C |
Raijintek Pallas |
37 °C |
59 °C |
Cooler
Master Hyper 103 |
36 °C |
60 °C |
Alpenföhn Matterhorn Pure |
36 °C |
61 °C |
Prolimatech Lynx |
35 °C |
63 °C |
Thermolab Bada
2010 |
39 °C |
64 °C |
Thermolab LP53 |
38 °C |
69 °C |
Scythe IORI
Scior-1000 |
39 °C |
65 °C |
Thermolab ITX30 |
38 °C |
75 °C |
Intel Stock |
39 °C |
83 °C |
To measure cooling capacity we took temperatures in idle and load
with the fans at 7 and 12 V. The idle temperature represents the lowest
temperature hit by the processor package after 10 minutes in idle. The load temperature is
the highest temperature hit by the processor package after one pass of wPrime v2.10. The
wPrime test takes 4 minutes and puts load on all 8 threads.
Room temperature is 25°C.
12V |
Idle |
Load |
Enermax Liqtech
120X |
31 °C |
44 °C |
Corsair H75 Single
Fan |
32 °C |
51 °C |
Noctua NH-U12S
Dual Fan |
33 °C |
51 °C |
Noctua NH-U12S
Single Fan |
33 °C |
53 °C |
Raijintek Themis
EVO |
33 °C |
54 °C |
Raijintek Nemesis Dual Fan |
33 °C |
54 °C |
Enermax ETS-T40
White Cluster |
34 °C |
54 °C |
Raijintek Nemesis Single Fan |
34 °C |
55 °C |
Prolimatech Lynx |
34 °C |
55 °C |
Scythe Ashura |
34 °C |
55 °C |
Raijintek Pallas |
36 °C |
56 °C |
Alpenföhn
Matterhorn Pure |
34 °C |
57 °C |
Cooler
Master Hyper 103 |
36 °C |
58 °C |
Scythe IORI
Scior-1000 |
37 °C |
60 °C |
Thermolab Bada
2010 |
39 °C |
64 °C |
Thermolab LP53 |
37 °C |
65 °C |
Thermolab ITX30 |
36 °C |
69 °C |
Intel Stock |
35 °C |
70 °C |
Fan Speeds
|
7 Volt |
12 Volt |
Raijintek Nemesis
Single Fan |
840 rpm |
1'180 rpm |
Raijintek Nemesis
Dual Fan |
780 rpm |
1'200 rpm |
Scythe Ashura |
600 rpm |
1'440 rpm |
Raijintek Pallas |
960 rpm |
1'440 rpm |
Noctua NH-U12S
Dual Fan |
900 rpm |
1'500 rpm |
Noctua NH-U12S
Single Fan |
900 rpm |
1'500 rpm |
Raijintek Themis
EVO |
960 rpm |
1'500 rpm |
Alpenföhn
Matterhorn Pure |
660 rpm |
1'530 rpm |
Prolimatech Lynx |
600 rpm |
1'740 rpm |
Enermax ETS-T40
White Cluster |
1'260 rpm |
1'860 rpm |
Thermolab Bada
2010 |
1'140 rpm |
1'980 rpm |
Corsair H75 Single
Fan |
1'200 rpm |
1'980 rpm |
Intel Stock |
1'260 rpm |
2'040 rpm |
Enermax Liqtech
120X |
1'270 rpm |
2'050 rpm |
Thermolab LP53 |
300 rpm |
2'180 rpm |
Scythe IORI
Scior-1000 |
280 rpm |
2'220 rpm |
Cooler
Master Hyper 103 |
1'580 rpm |
2'400 rpm |
Thermolab ITX30 |
1'620 rpm |
2'580 rpm |
Fan speeds (RPM) at 7 and 12 V.
Noise Levels
|
7 Volt |
12 Volt |
Intel Stock |
33.3 dBA |
37.1 dBA |
Noctua NH-U12S
Single Fan |
32.3 dBA |
37.4 dBA |
Raijintek Nemesis Single Fan |
34.6 dBA |
38.0 dBA |
Alpenföhn
Matterhorn Pure |
32.3 dBA |
38.4 dBA |
Thermolab ITX30 |
33.4 dBA |
38.9 dBA |
Raijintek Pallas |
34.7 dBA |
39.3 dBA |
Cooler
Master Hyper 103 |
34.2 dBA |
39.5 dBA |
Noctua NH-U12S
Dual Fan |
33.4 dBA |
39.6 dBA |
Thermolab LP53 |
31.2 dBA |
39.7 dBA |
Raijintek Themis
EVO |
33.9 dBA |
40.1 dBA |
Scythe IORI
Scior-1000 |
32.8 dBA |
40.3 dBA |
Prolimatech Lynx |
33.0 dBA |
40.3 dBA |
Thermolab Bada
2010 |
32.3 dBA |
40.4 dBA |
Enermax Liqtech
120X |
33.4 dBA |
40.6 dBA |
Enermax ETS-T40
White Cluster |
33.3 dBA |
40.7 dBA |
Scythe Ashura |
32.0
dBA |
41.0 dBA |
Corsair H75 Single
Fan |
34.5 dBA |
41.7 dBA |
Raijintek Nemesis Dual Fan |
36.1 dBA |
43.6 dBA |
Decibel meter (Voltcraft SL-200) has been placed 1 meter away from the
cooler. Measurements are conducted in a quiet room, where there are no other noise source. 32 dBA is the lowest
we can get in our room. Also here
the measurements are conducted at 7 and 12 V.